4 SERVICE RT2047 DSC - PART II
AA119
AA119
ceramic
1nF
1nF
ceramic
To multimeter
RF
Metal tube
Insulating material
10.00 12.00 70.00
ø10
25079
LAYOUT OF THE PROBE
TEST PROBE
4.4 CALIBRATION OF THE TEST PROBE
For some test probe measurements it is necessary to use a test probe calibrated with a specified multi
meter.
NECESSARY EQUIPMENT FOR THIS PROCEDURE:
1. Diagram for the measurements
2. Test probe
3. Multi meter
4. New factory adjusted RT2047
4.5 PROCEDURE FOR CALIBRATION
1. Switch on the set.
2. Select channel 28.
3. Remove coax cable from the soldering point for F
L01
to RX on the RX-Synthesizer and replace
it with a 50 resistor.
4. Connect the test probe to the point mentioned above and record the result in the diagram.
5. Remove the resistor and solder back the coax cable.
6. Follow the procedure mentioned above by measuring the levels from F
L01
to TX on the RX-
Synthesizer and the TX drive level from the TX-Exciter.
All other test probe measurements are relative and ought to be measured with the same test probe and
recorded in the diagram.
PAGE 4-2